Microlearning · Module 3 of 3 · Degraded operation
When the automatic systems no longer help
What the technology no longer secures, the procedure has to secure.
The door interlock and the brake control protect normal operation. At Styal there was no written guidance for degraded operation. Using the chain and three scenarios, this module shows where the course of events could have held and what an instruction needs when its last step does not work.
- About 7 minutes
- 4 questions with feedback
- No sign-in; answers are not stored
What this is about
After the isolation at Styal, only the procedure protects, and there is no written guidance for this situation. After this module you can, using the case:
- recognize what is missing from a fault-finding instruction that has no way out,
- put the steps after an isolation into the order of the Rule Book,
- match each of the three scenarios to the link of the chain it addresses,
- explain why a no-fault-found case has to be assessed before the vehicle goes back into service.
Each voice is followed by a question, and an application task comes at the end. If your answer is right, you get more depth. If it is wrong, a hint shows where the answer is in the case note, and you get a second attempt; after that, the solution appears with the reasoning.
The three people are fictitious roles at another operator and at a train manufacturer, not people involved in the case. They speak about what the report describes; their view is my reading.
- Back
- Next
- Check answer
- Please choose an answer first.
- Please make a choice for every row.
- Correct.
- The second attempt is not right either. Here is the solution.
- Part
- of
- Move up
- Move down
- Use “Move up” and “Move down” to reorder the steps.
- Choose the matching item for each row.
- Please choose
- wrong choice
- correct
- Answered correctly at the first attempt: {n} of {total} questions. Nothing is stored.
- Start again
The scene
- Operator’s control (maintenance controller and duty control manager)
- Signaler
- Isolating switches EBS (brake circuit) and TIS (traction interlock), vertical when normal
- Light “safety systems isolated”
- Door interlock indicator on the driver’s desk
- Leading cab
- Rear cab
- Doors on the platform side
- Driver
- Conductor
Styal, 3 May 2023. After the TIS is isolated, the brakes still do not release. Control’s flow chart ends with the EBS, and there is no written guidance for this situation. After 25 minutes at the platform the train departs with five doors open, without dispatch and without the signaler’s instruction.
On 25 May the fault occurred again during shunting and was traced to the leading cab. According to the report, the brakes at Styal would have released from the rear cab.
The whole case in brief is in the overview of the modules. The drawing shows the analysis: control, the switches and lights, the location of the fault and the doors are marked.
A flow chart with no way out
On the phone, I follow the flow chart. The “Unable to release brakes” flow chart at Styal applied to all fleets, contained actions for diesel engines although the train was electric, and ended with the EBS. It did not ask which cab the fault occurred in, and it did not say what applies when the last step does not work. Then people improvise, under time pressure and on the phone.
Report, check, move on instruction
After an isolation, I am the check that the door interlock no longer provides. Under the Rule Book the conductor checks all doors on both sides and travels in the rear cab, again after every door release. For that, the conductor has to know that something was isolated. At Styal the conductor was not told, and the operator’s dispatch plan contained nothing for degraded operation.
Where the chain could have held
For me, degraded operation does not begin on the platform but in the depot. On 24 April the fault had already occurred once; the depot did not find it and released the unit back into service. According to the report, whether a fault counted as a safety or a performance fault was decided by undocumented judgment. What a manufacturer writes about intermittent faults and their consequences for safety functions can support this decision.
The report does not reproduce the manufacturer’s information. This voice shows how the case note reads the role of the manufacturer’s information.
Back to the depot
This task leads back to the start of the chain. Imagine you are writing the information a depot uses to decide whether a vehicle goes back into service.
Apply it to your documentation
Think of an instruction in your documentation for a fault, for example fault finding, a flow chart or emergency operation.
Check this instruction with the questions from the case note:
- Does the instruction ask where, and in which component, the fault occurs?
- What does the instruction say when its last step does not work?
- Is operation with defective equipment defined and practiced?
- How is a no-fault-found case assessed before the product goes back into service?
The key points in three sentences
- What the technology no longer secures, a defined procedure has to secure: report, check, move on instruction, restore.
- An instruction for a fault needs a location and a way out: where the fault occurs and what applies when the last step does not work.
- The chain begins in the depot. A no-fault-found case is information that has to be assessed.
Basis and source
This microlearning does not replace instruction. Procedures, instruction and supervision in rail operation remain with the operator.
Source
Report 07/2024 of the British Rail Accident Investigation Branch (RAIB), “Unsafe movement of a train at Styal station, 3 May 2023”, as retold in the case note “Five open doors”. Roles, quotes and drawings are my own. How the series is built is described in the overview of the modules.