Microlearning · Module 1 of 3 · Isolation

Isolating is not securing

The light is on, and the fault is still there.

In machine and plant safety, lockout/tagout removes energy so that a person can work safely; rail does not use this term. An isolating switch in service switches off a protective function so that the train can move again. Using the Styal case, this module shows what follows for authorisation, reporting, checking and information.

  • About 7 minutes
  • 4 questions with feedback
  • No sign-in; answers are not stored

What this is about

During a fault, a driver isolates two safety systems, one of them the door interlock. After this module you can, using the case:

  • distinguish the direction in which an isolation in service works from the direction in which lockout/tagout works,
  • match the elements of lockout/tagout to Northern’s rules for an isolation,
  • name which protective function still worked after the TIS was isolated and which did not,
  • select the information that has to be known before an isolation is authorised.

Each voice is followed by a question, and an application task comes at the end. If your answer is right, you get more depth. If it is wrong, a hint shows where the answer is in the case note, and you get a second attempt; after that, the solution appears with the reasoning.

The three people are fictitious roles at another operator and at a train manufacturer, not people involved in the case. They speak about what the report describes; their view is my reading.

The scene

  • Operator’s control (maintenance controller and duty control manager)
  • Signaller
  • Isolating switches EBS (brake circuit) and TIS (traction interlock), vertical when normal
  • Light ‘safety systems isolated’
  • Door interlock indicator on the driver’s desk
  • Leading cab
  • Rear cab
  • Doors on the platform side
  • Driver
  • Conductor

Styal, 3 May 2023, after 15:09. The brakes of the train do not release. The maintenance controller guides the driver through fault finding by phone, following a flow chart.

The driver operates the EBS isolating switch, with no effect. For the TIS, which the flow chart does not mention, the maintenance controller obtains verbal authorisation from the duty control manager in a brief side conversation. With the TIS operated, the door interlock is out of action, the ‘safety systems isolated’ light is on, and the brakes still do not release.

The whole case in brief is in the overview of the modules. The drawing shows the situation after the isolation.

What isolating means here

Technical writer at a train manufacturer fictitious role, thought experiment

‘Isolating’ sounds like protection. On a train in service it means the opposite: the switch takes a protective function away so that the train can move despite the fault. Afterwards people are not better protected but less protected. When I describe an isolating switch, this direction has to come first, not in a footnote.

The report does not reproduce the manufacturer’s information. This voice shows how the case note reads the role of the manufacturer’s information.

Question 1 of 4

What distinguishes isolating the TIS in service from lockout/tagout?

That is not correct. In the case note, read the paragraph ‘The decisive difference’ in the section ‘Rail has other words for lockout/tagout’. Then try again.

Solution and explanation

Solution: b. The two work in opposite directions.

Lockout/tagout protects the person at the machine. The isolation in service takes a protective function away so that the train can move. There is no lock and no tag; their job is taken over by authorisation, reporting, checking and restoring. Information about an isolating switch has to name this direction, or the switch is read as a safeguard.

Rules instead of lock and tag

Maintenance controller at another operator, fictitious role

On the phone, an isolation is quickly said. At Styal, the authorisation for the TIS came about in a brief side conversation while the call with the driver went on. No form B was completed, and neither the signaller nor the conductor was told. The rules existed. But they only work when every step happens as a step of its own.

Question 2 of 4

Match each of Northern’s rules for an isolation to the element of lockout/tagout whose job it takes over.

  • The ‘safety systems isolated’ light, form B, and telling the signaller and the conductor
  • Isolation only with explicit authorisation from the duty control manager.
  • Until reset, the train moves only on the signaller’s instruction.
  • After every door release, the conductor checks all doors on both sides again.
  • Only depot maintenance staff or an engineering technical inspector can reset.

Choose from:

  • Authorisation
  • Lock
  • Tag
  • Check
  • Restore

That is not correct; at least one match is wrong. The table in the section ‘Rail has other words for lockout/tagout’ puts both sides next to each other. Then try again.

Solution and explanation

Solution: Authorisation — explicit authorisation from the duty control manager; Lock — reset only by the depot or an engineering technical inspector; Tag — light, form B and telling others; Check — a new door check after every door release; Restore — moving only on instruction until reset.

In an isolation, rules take over the job of lock and tag, and rules only work when they are followed. At Styal the light was on. Form B, the report to others, the new check and the instruction were missing.

What still protects afterwards

Train driver at another operator, fictitious role

Normally the TIS is the last step, and then the train moves. At Styal the brakes still did not release, and the isolation stayed in effect, because only the depot or an engineering technical inspector could reset it. From that moment on, only the procedure protects. And I need to know which technology still works and which does not.

Question 3 of 4

The TIS is isolated. Which protective function still worked at Styal afterwards?

That is not correct. In the case note, read the step ‘The last safeguard’ and try again.

Solution and explanation

Solution: b. The low speed relay worked even with the TIS isolated.

With the TIS, the door interlock was out of action; the train could move off with doors open. The relay closed the doors only once the train was moving. Anyone who authorises an isolation needs to know which protective functions still work afterwards and which do not. This belongs in the manufacturer’s information, in control’s instructions and in training.

Before the authorisation

This task brings the three voices together. Imagine you are revising the information control uses to decide on isolating the TIS.

Question 4 of 4

What does control need to know before it authorises the isolation? Select all that apply.

That is not correct; at least one choice is wrong. In the case note, read the weak point ‘An isolation that achieves nothing’ and try again.

Solution and explanation

Solution: a, b and d. The light does not replace telling others.

The light shows only in the cab that something is isolated. The signaller and the conductor learn of it only when they are told. At Styal the remaining information was missing: the flow chart did not mention the TIS and said nothing about what applies after an isolation.

Apply it to your documentation

Think of a product in your documentation whose protective functions can be switched off, bypassed or isolated during a fault.

Check the information about this function with the questions from the case note:

  • Which protective functions does the switch disable, and which remain effective?
  • Does it say at the start that the function no longer protects afterwards?
  • Who authorises an isolation, who has to be told, and how is this confirmed?
  • Who may reset it, and what applies until then?

The key points in three sentences

  1. An isolation in service works the other way round from lockout/tagout: it takes a protective function away so that the train can move.
  2. There is no lock and no tag. Authorisation, reporting, checking and restoring have to take over their job.
  3. Anyone who authorises an isolation needs to know what still protects afterwards and what applies when it does not fix the fault.

Basis and source

This microlearning does not replace instruction. Procedures, instruction and supervision in rail operation remain with the operator.

Source

Report 07/2024 of the British Rail Accident Investigation Branch (RAIB), ‘Unsafe movement of a train at Styal station, 3 May 2023’, as retold in the case note ‘Five open doors’. Roles, quotes and drawings are my own. How the series is built is described in the overview of the modules.